Scale 1:2 · third-angle projection · all dims in mm
Drawing titleModular Actuator — Base Assembly
Drawn byR. Vasquez
Date2026-09-22
Sheet01 / 04
Dimension schemeDimensions are placed outside the outline where possible and tied in
with extension lines that stop short of the geometry, as convention requires.ProjectionThird-angle projection: the view to the right of the front elevation is the
right-hand side, not the left.HatchingThe section uses a single 45° hatch at constant pitch, indicating one
material throughout the cut.Centre linesChain-dotted axes mark the bore and the overall symmetry, in yellow so
they never read as object lines.